Planning the power supply for your office unit
When connecting electricity to an office unit, everything starts with a good plan. First determine where the unit will stand and how far it is from the existing meter cupboard or power connection. It is also important to consider whether the unit is used temporarily or permanently, because this affects the way of connecting.
A temporary office unit can sometimes be supplied via a construction power supply or a separate distribution board, while a permanent unit usually needs a fixed connection. Also take future extensions into account, such as extra workstations, charging points or heavier equipment, so that the installation is not immediately made too small.
Via the existing meter cupboard or your own connection?
There are roughly two ways to supply an office unit with power:
- Via the existing meter cupboard. An installer runs a cable from a free circuit or an extra circuit in your meter cupboard to the unit. This is often the simplest and cheapest route if the unit is close to the main building and the existing connection is heavy enough.
- Its own grid connection. The unit gets its own meter and connection from the grid operator. This is useful if the unit is far from the main building, if you want to measure the consumption separately or if your current connection is too light. You request a new or heavier connection from the grid operator, for example via mijnaansluiting.nl.
Bear in mind that realising a new grid connection can take some time. So request it in good time, well before the unit is delivered.
Determining the connection capacity for lighting and equipment
The required connection capacity depends on all electrical appliances used in the office unit. Lighting and laptops require relatively little power, but electric heating, air conditioning, coffee machines, servers or printers can raise the load considerably.
So make an overview of all appliances and their power, and add a safe margin. This prevents circuits from becoming overloaded or fuses regularly tripping. With several workstations it is wise to spread sockets generously and not connect everything to one circuit. Our units come with a 3-phase connection as standard (3 × 25 A). An electrician can help calculate the connection value you need at your location.
Example: where does the power go?
- Low consumption: LED lighting, laptops, monitors, charging phones.
- Medium: printers, fridge, router and network equipment.
- High or peak consumption: air conditioning or electric heating, kettle, coffee machine, microwave, electric boiler, charging point.
Appliances from the last group in particular determine how heavy the connection must be. Also read heating and cooling of an office unit.

Installing a safe consumer unit in the unit
An office unit often needs its own consumer unit or distribution board, especially when several power points, lighting and appliances are connected. In this consumer unit the different circuits are distributed, for example for lighting, wall sockets, heating and any outdoor lighting.
It is important that the installation is fitted with residual-current devices and suitable circuit breakers, so that the power is switched off automatically in case of a short circuit, overload or leakage current. The earthing must also be properly arranged, as this plays an important role in the safety of users. Always have the consumer unit installed by a qualified electrician, so that it meets the applicable standards, such as NEN 1010 for low-voltage installations.
With a Voordeelunits unit the installation inside is already done: the unit has all connections ready inside. Connecting to electricity, water and sewer on site is done by a local specialist. When ordering, discuss which circuits and how many sockets you need.
Running cables from the meter cupboard to the office unit
The cable from the meter cupboard to the office unit must be suitable for the power, the distance and the conditions in which it is laid. For an outdoor installation an underground cable is usually used, which is resistant to moisture and mechanical load. This cable must be buried at the correct depth and protected where necessary, for example at passages or places where vehicles drive.
The cable cross-section is also important: with a cable that is too thin, voltage loss can occur, causing appliances to work less well or the cable to get too hot. A neat route, a good entry into the unit and waterproof connections ensure a reliable and durable installation.
Tip: dig the trench for the power cable at the same time as the trenches for water, sewer and a data cable. Lay an extra conduit alongside, so that you can easily pull in another cable later. You can read more about internet in internet and network facilities in an office unit and about water in arranging a water connection for an office unit.
Inspection and maintenance of the electrical installation
After connecting the electricity it is wise to have the installation checked or inspected. This looks at whether the consumer unit, wiring, earthing, protections and sockets have been installed safely and correctly. For business office units a periodic check can moreover be mandatory or strongly recommended, for example because of insurance, working-conditions (Arbo) requirements or internal safety rules.
Maintenance also remains important after commissioning: regularly check that sockets are not damaged, cables are not loose and circuits are not structurally overloaded. When extending the office unit or installing new equipment it is smart to have the installation assessed again.

Solar panels or a charging point at the office unit?
Do you want solar panels on or near the unit later, or a charging point for an electric car? Then take that into account in the design already. A charging point often requires its own circuit and sometimes a heavier connection. Solar panels need a separate circuit for the inverter. By discussing this in advance with your installer, you will not have to dig again or replace the consumer unit later.
Conclusion
Connecting electricity to an office unit takes more than just laying a cable inside. By mapping out the power need in advance, installing the right consumer unit, using suitable cabling and having the installation checked, you create a safe and comfortable workplace. If in doubt, always call in a certified electrician; that way you can be sure the office unit is connected reliably, safely and in a future-proof way.